LASMIK-UROLOGIST is a multifunctional physiotherapeutic complex for carrying out procedures of combined and conjoined laser therapy. LASMIK-UROLOGIST is used for efficient treatment of patients in urology, andrology, nephrology, proctology and gynecology.
The complete set of the LASMIK-UROLOGIST complex depends on the application area. The delivery of its components is possible in any combination.
Complete set
Contains
Therapeutic Indications
Basic Complex LASMIK-URLOGIST
Basic Complex LASMIK-URLOGIST
Vibromagnetic laser head VMLH-10
Prostatitis
A set of emitting heads and nozzles
Laser Head LO-904-20
Laser Head KLO -635-15
Matrix head of pulsed illumination ML-904-80
Optical nozzles P1, P2, P3
Mirror and magnetic nozzles
Cystitis (acute and chronic)
Peyronie’s Disease
Pyo-septic postoperative complications
Urethritis
Prostatitis
Kidney amyloidosis chronic renal failure
Pyelonephritis (acute, chronic)
Diabetic nephropathy
Impotence and frigidity
Ejaculation disorders
Infertility
Pathology of spermatogenesis neurotic sexual disorders
LASMIK-LLNP complex for erectile dysfunction treatment
LASMIK-03 device
Laser head LO-LLNP
Special cups for laser-vacuum massage
Erectile dysfunction
Complex for electrotherapy
ELFOR-PROF device
Rectal (vaginal) electrode – 10 pcs.
Uretroprostatitis
Chronic urethroprostatitis
Impotence
Peyronie’s disease (fibroplastic induration of penis)
Additional equipment
Protective glasses ZN-22 «MATRIX»
Glasses are designed to protect the doctor’s and patient’s eyes from direct and reflected laser illumination.
LASMIK-UROLOGIST device and all the emitting heads and nozzles to it have a Registration Certificate and Declaration of Conformity of the Ministry of Health and Social Development of the Russian Federation.
LASMIK-UROLOGIST, LASMIK-03 devices and pulsed emitting heads have 5 years guarantee period. Emitting heads of continuous illumination and ELFOR-PROF device have 1 year guarantee.
BASIC SET OF LASMIK-UROLOGIST COMPLEX
LASMIK-UROLOGIST base unit
The base unit allows you to set all the parameters of the emitting heads: power, frequency of laser illumination, exposure time, oscillation amplitude of vibromagnetic laser head VMLH-10. Laser power is controlled by a photodetector.
The base unit LASMIK-UROLOGIST has three inputs for connecting emitting heads. The main input is used to connect the VMLH-10 The other two are for connecting Matrix head LO-LLNP and for transdermal exposure and intravenous blood illumination.
Vibromagnetic laser head VMLH-10
Active factors:
Laser illumination with a wavelength of 0.63 microns, power 10 mW
Permanent ring magnet 25 mT
Vibration of the applied part with a frequency of 1-10 Hz
The vibromagnetic laser head VMLH-10 is designed for apparatus massage of the prostate and is a flexible rectal head, in the applied part of which there is a magnet with an induction of 25 mT and a laser illumination diffuser. Flexible output allows vibration with a frequency of 1-10 Hz and a maximum amplitude of 5 mm. The engine and laser are located inside the head body.
A SET OF LASER EMITTING HEADS AND NOZZLES
Laser emitting head LO-904-20 – 2 pcs.
Active factor: pulsed infrared laser illumination with a wavelength of 890 nm and adjustable power from 0 to 20 watts.
The emitting head works in a pulsed mode, provides deep penetration of infrared illumination for therapeutic effects in urology, nephrology, proctology, etc. It is often used paravertebral in urology, so it is recommended to purchase 2 emitting heads of this type.
Laser emitting head KLO-635-15
Active factor: continuous red laser illumination with a wavelength of 630 nm and adjustable power from 0 to 15 mW
The laser emitting head of the red spectrum KLO-635-15 operates in a continuous mode. It is most often used with optical nozzles P1, P2, P3 for intracavitary exposure. It is also used in combination with the A3 nozzle to affect acupuncture points.
Matrix laser head of pulsed illumination ML-904-80
Active factor: infrared laser illumination with a wavelength of 890 nm and adjustable power from 0 to 80 W.
The emitting head ML-904-80 is a matrix of 8 laser diodes. It has a large exposure area and an increased power of laser illumination. It is used to affect the projections of the internal organs, zones of Zakharyin-Ged, projection of immunocompetent organs.
Proctology nozzle P1
Illumination output: a spot with a diameter of 5-10 mm at an angle of 120 ° with a local distribution of power density.
For prostate illumination (rectally).
Proctology nozzle P2
Illumination output: cylinder with a diameter of 9 mm and a length of 25 mm.
It is used in urology to illuminate the prostate (rectally) or in proctology to illuminate the walls of the rectum.
Proctology nozzle P3
Illumination output: a cylinder with a diameter of 9 mm and a length of 25 mm.
It is used to illuminate the walls of the rectum (anal fissures, hemorrhoids, etc.)
Magnetic nozzle ZM50
Magnetic nozzle with a magnetic field of 50 mT. It is used with heads of LO and KLO type
A constant magnetic field provides higher treatment efficiency when used in combination with laser illumination.
Magnetic nozzle ММ50
Magnetic nozzle with a magnetic field of 50 mT. It is used with matrix emitting head ML-904-80.
A constant magnetic field provides higher treatment efficiency when used in combination with laser illumination.
Mirror nozzle ZN35
It is designed for laser emitter protection, hygiene procedures and reduction of laser illumination scattering in contact exposure.
LASMIK-LLNP complex for erectile dysfunction treatment.
Laser therapy and laser-vacuum massage device LAZMIK-03
The main active factor: vacuum
LASMIK-03 device is used to create negative pressure during the erectile dysfunction treatment procedure using the local laser negative pressure method (LLNP).
The device has buttons for regulating the pressure and turning off the device. During the procedure the patient, in case of discomfort, can reduce the amount of vacuum in the cup himself and reduce the discomfort.
Laser head of continuous illumination LO-LLNP
Active factors:
Pulsed infrared laser illumination with a wavelength of 890 nm, power 70 W
Red continuous laser illumination with a wavelength of 630 nm, power 60 mW
Laser emitting head LO-LLNP is connected to two channels of the base unit LASMIK-UROLOGIST. When using a LO-LLNP laser head, it is recommended to switch on the base unit alternately laser illumination of the red spectrum on channel 1, then laser illumination of the infrared spectrum on channel 2.
In the laser head LO-LLNP, lasers of red and IR spectra are used for LASMIK-UROLOGIST device, whereas other similar devices use low-efficient LEDs.
Special cups for LLNP
Special B-LLNP cups are used for carrying out the local laser negative pressure procedure. The cup is connected to the LASMIK-03 device with a hose, the laser head LO-LLNP is put on the cup. After the procedure, the entire structure should disassembled for sterilization and storage.
COMPLEX for ELECTROTHERAPY
Electrotherapy device Ellfor-Prof Active factor: galvanic current Elfor-Prof device allows to carry out procedures of galvanization and electrophoresis.
Galvanization – the impact of a continuous constant current of low power (up to 50 mA), supplied to the body In contact use, by means of electrodes. Galvanic current itself has an the effect. It enhances the synthesis of biologically active substances, changes the conductivity of the nerve trunks, improves blood circulation in tissues. The reactions arising under the impact of current have anti-inflammatory, analgesic, metabolic effects. Electrophoresis is the simultaneous impact of direct current and drug administered with it. It is used in urology in treating the following diseases: urethroprostatitis, chronic urethroprostatitis, impotence, Peyronie’s disease (fibroplastic induration of the penis).
In urology and venereology, intracavitary electrophoresis is often used. For example, for chronic prostatitis, electrophoresis is carried out with rectal technique using intracavitary disposable electrodes.
Disposable rectal (vaginal) electrodes
The rectal (vaginal) electrode is designed for all types of low-frequency electrotherapeutic procedures.
The electrode is made of a cotton tampon “TAMPAX”, in the inner part of which along the entire length an electrically conductive cord is stitched to ensure uniform distribution of the electric potential. Inside the electrode there is an elastic tube that allows to to fill a tampon with a medication using a syringe.
The electrode is placed inside the endotracheal tube and is equipped with a piston tube, which is a system for introducing the electrode into the cavity.
LASMIK-SF STAND FOR LASMIK-UROLOG COMPLEX
LASMIK-SF stand allows you to use the working space efficiently and conveniently arrange all the devices of the LASMIK-UROLOGIST complex at hand.
There are special holders for 5 laser emitting heads that ensures aginst the accidental fall of the emitter and its damage.
The wheel supports of the LASMIK-SF stand allow it to be easily moved around the medical center.
LASMIK-UROLOGIST STANDARD
LASMIK-UROLOGIST STANDARD is designed for vibromagnetic laser massage of prostate and LLNP-therapy procedures for erectile dysfunction treatment using local laser decompression technique.
Complete set
Contains
Therapeutic Indications
Basic Complex LASMIK-URLOGIST
Basic Complex LASMIK-URLOGIST
Vibromagnetic laser head VMLH-10
Prostatitis
LASMIK-LLNP complex for erectile dysfunction treatment
LASMIK-03 device
Laser head LO-LLNP
Special cups for laser-vacuum massage
Erectile dysfunction
LASMIK-UROLOGIST device and all the emitting heads and nozzles to it have a Registration Certificate and Declaration of Conformity of the Ministry of Health and Social Development of the Russian Federation.
LASMIK-UROLOGIST, LASMIK-03 devices and pulsed emitting heads have 5 years guarantee period. Emitting heads of continuous illumination have 1 year guarantee.
BASIC SET OF LASMIK-UROLOGIST COMPLEX
LASMIK-UROLOGIST base unit
The base unit allows you to set all the parameters of the emitting heads: power, frequency of laser illumination, exposure time, oscillation amplitude of vibromagnetic laser head VMLH-10. Laser power is controlled by a photodetector.
The base unit LASMIK-UROLOGIST has three inputs for connecting emitting heads. The main input is used to connect the VMLH-10 The other two are for connecting Matrix head LO-LLNP and for transdermal exposure and intravenous blood illumination.
Vibromagnetic laser head VMLH-10
Active factors:
Laser illumination with a wavelength of 0.63 microns, power 10 mW
Permanent ring magnet 25 mT
Vibration of the applied part with a frequency of 1-10 Hz
The vibromagnetic laser head VMLH-10 is designed for apparatus massage of the prostate and is a flexible rectal head, in the applied part of which there is a magnet with an induction of 25 mT and a laser illumination diffuser. Flexible output allows vibration with a frequency of 1-10 Hz and a maximum amplitude of 5 mm. The engine and laser are located inside the head body.
LASMIK-LLNP complex for erectile dysfunction treatment
The main active factor: vacuum
LASMIK-03 device is used to create negative pressure during the erectile dysfunction treatment procedure using the local laser negative pressure method (LLNP).
The device has buttons for regulating the pressure and turning off the device. During the procedure the patient, in case of discomfort, can reduce the amount of vacuum in the cup himself and reduce the discomfort.
Laser head of continuous illumination LO-LLNP
Active factors:
Pulsed infrared laser illumination with a wavelength of 890 nm, power 70 W
Red continuous laser illumination with a wavelength of 630 nm, power 60 mW
Laser emitting head LO-LLNP is connected to two channels of the base unit LASMIK-UROLOGIST. When using a LO-LLNP laser head, it is recommended to switch on the base unit alternately laser illumination of the red spectrum on channel 1, then laser illumination of the infrared spectrum on channel 2.
In the laser head LO-LLNP, lasers of red and IR spectra are used for LASMIK-UROLOGIST device, whereas other similar devices use low-efficient LEDs.
Special cups for LLNP
Special B-LLNP cups are used for carrying out the local laser negative pressure procedure. The cup is connected to the LASMIK-03 device with a hose, the laser head LO-LLNP is put on the cup. After the procedure, the entire structure should disassembled for sterilization and storage.
LASMIK-SF STAND FOR LASMIK-UROLOG COMPLEX
LASMIK-SF stand allows you to use the working space efficiently and conveniently arrange all the devices of the LASMIK-UROLOGIST complex at hand.
There are special holders for 5 laser emitting heads that ensures aginst the accidental fall of the emitter and its damage.
The wheel supports of the LASMIK-SF stand allow it to be easily moved around the medical center.
LASMIK-UROLOGIST MINI
LASMIK-UROLOGIST MINI – the basis of the whole complex. The minimum set allows for the procedure vibro-magnet massage of prostate. In the future, the complex can be expanded by purchasing equipment for LLNP, laser therapy, ILBI, electrotherapy.
Complete set
Contains
Therapeutic Indications
Basic Complex LASMIK-URLOGIST
Basic Complex LASMIK-URLOGIST
Vibromagnetic laser head VMLH-10
Prostatitis
LASMIK-UROLOGIST device and all the emitting heads and nozzles to it have a Registration Certificate and Declaration of Conformity of the Ministry of Health and Social Development of the Russian Federation.
LASMIK-UROLOGIST have 5 years guarantee period. VMLH-10 have 1 year guarantee.
BASIC SET OF LASMIK-UROLOGIST COMPLEX
LASMIK-UROLOGIST base unit
The base unit allows you to set all the parameters of the emitting heads: power, frequency of laser illumination, exposure time, oscillation amplitude of vibromagnetic laser head VMLH-10. Laser power is controlled by a photodetector.
The base unit LASMIK-UROLOGIST has three inputs for connecting emitting heads. The main input is used to connect the VMLH-10 The other two are for connecting Matrix head LO-LLNP and for transdermal exposure and intravenous blood illumination.
Vibromagnetic laser head VMLH-10
Active factors:
Laser illumination with a wavelength of 0.63 microns, power 10 mW
Permanent ring magnet 25 mT
Vibration of the applied part with a frequency of 1-10 Hz
The vibromagnetic laser head VMLH-10 is designed for apparatus massage of the prostate and is a flexible rectal head, in the applied part of which there is a magnet with an induction of 25 mT and a laser illumination diffuser. Flexible output allows vibration with a frequency of 1-10 Hz and a maximum amplitude of 5 mm. The engine and laser are located inside the head body.
LASMIK-SF STAND FOR LASMIK-UROLOG COMPLEX
LASMIK-SF stand allows you to use the working space efficiently and conveniently arrange all the devices of the LASMIK-UROLOGIST complex at hand.
There are special holders for 5 laser emitting heads that ensures aginst the accidental fall of the emitter and its damage.
The wheel supports of the LASMIK-SF stand allow it to be easily moved around the medical center.